Measurement - Dew Point

What is Dew Point?

The Dew Point is the lowest temperature that allows water vapour to remain in a gas without condensing to a liquid state. As the air or gas temperature drops, its ability to absorb water vapour drops until it becomes completely saturated and below this dew point temperature, water droplets will start to form.

In pressurised systems such as compressed air distribution networks, the dew point is directly related to the temperature AND system pressure. As pressure increases, the dew point temperature also rises meaning that the potential for vapour to condense out occurs at a higher temperature. In practice this can mean that instead of the condensing temperature being quite low, the dew point could be at or above ambient temperature.

Why do I need Dew Point Measurement?

Industrial compressed air and gas systems can suffer damage from water contamination directly or through the water subsequently freezing and expanding. Having water vapour in the air or gas can also affect process or product quality. Removing water contamination through filters and drying systems is common practice but as the dew point (and potential for damaging condensation) changes with pressure, the risk of damage will vary throughout a plant.

ISO 8573-1 defines a range of purity classes for compressed air including water with the measurement expressed in terms of pressure dew point. ISO 8573-3 is the section that defines measurement methods for humidity and ISO 8573-9 for liquid water.

Measuring the dew point can be a simple process and should be continuously monitored according to the plant risk analysis recommendations. This needs to occur at the drying plant before the distribution network and also at critical points of use. By measuring the dew point, efficient control of the drying/filtering system can be achieved to optimise the running costs of the compressed air/gas system.

It is common to have a secondary dew point sensor installed downstream of the dryer to offer redundancy should the dryer start to fail and wet air enters the distribution system. This provides an alarm point and  with prompt action can save huge costs for damages and lost production due to water ingress.

Particular emphasis should be placed on any part of the system where the pressure increases or the ambient temperature decreases as these are the situations where problems can occur quickly. For example, the air ring main leaves one building to go to another and the ambient outside air is or can be significantly lower than the indoor ambient. Additional drying capability may be needed and monitored in order to prevent condensation as the pipe leaves the building.

Monitoring the dew point is a key indicator of system health that can be used to guide maintenance tasks as well as maintain plant compliance with the purity classes set in ISO 8573-1. 

Refrigerant dryers are used for non-critical applications and are tested to a limit of <=+3degC for ISO 8573-1 Class 4 compliance. A dew point sensor with a range from -20degC to +50degC would be an ideal solution for this requirement.

Desiccant dryers provide much dryer air and are commonly tested to a limit of <=-40degC for ISO 8573-1 Class 2 compliance. A dew point sensor with a range from -50degC or -60degC to +20degC would be an ideal solution for this requirement. 

Advanced drying solutions to target the ISO 8573-1 Class 1 compliance limit of <=-70degC would suggest a dew point sensor with a range from -100degC for accurate readings at such low humidity.

Dew Point Sensors

S211 -60degC Dew Point Sensor 

S215 -20degC Dew Point Sensor

S220 -100degC Dew Point Sensor

S230 - S231 -100degC Dew Point Sensors

S305 Dew Point Monitor

S520 Smart Dew Point Meter

S505 Handheld Dew Point Meter (discontinued)

S201 Dew Point Sensor (discontinued)

S212 -50degC Dew Point Sensor (discontinued)

Related Articles

ISO 8573 Air Purity

Not sure which valve or measurement solution is best?
Use our experience to guide you...

For a deeper understanding of which valve or instrument would be best for you please call or email us now so that we can save you time and ensure you can make a truly objective decision for your company.

Contact Us

Get in Touch

+44 (0) 1443 772500 / 02922 780798

Red Dragon Limited T/A
Measure Monitor Control
Unit 15 Abergorki Industrial
Estate
Ynyswen Road
Treorchy
South Wales
CF42 6DL
United Kingdom
EORI: GB791056521000

Got a Question?

Need assistance with a product or an enquiry? Fill in the form below and we will get in touch with you as soon as possible:

The contact form requires that you configure reCAPTCHA in the site configuration.

The contact form requires that you select an email template.